A RESOURCE FOR INDUSTRY May-June 2018 1. Calibration of Venturimeter of size 950mm at LWFL & Testing of 600mm Valve at WFL. A Venturimeter of size 950 mm was calibrated at Large Water Flow Laboratory of FCRI and a Valve of size 600 mm was tested at Water Flow Laboratory 950 mm Venturimeter under calibration at LWFL Testing of 600 mm Valve at WFL 1 2. Calibration of EMF at LWFL & FL testing of Globe Valve at Valve Cavitation and Research Centre Calibration of an Electro Magnetic Flowmeter of size 450mm has been completed at Large Water ...
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 03 | Mar 2019 www.irjet.net p-ISSN: 2395-0072 EXPERIMENTAL STUDY ON FLOW THROUGH VENTURIMETER 1 2 3 4 5 J. Ahamed Jahith , M. Aadithya , L. Alwin Aadaikalaraj , R. Ashutosh Singh , G. Vaithiyanathan 1,2,3,4UG Student, Department of Civil Engineering, Valliammai Engineering College, Tamilnadu, India 5Assistant professor (O.G), Department of Civil Engineering, Valliammai Engineering College, Tamilnadu, India ---------------------------------------------------------------------***---------------------------------------------------------------------- Abstract - An attempt to study and prepare the computational model of a venturimeter, which can be used as an efficient and easy means for calibration ...